Pressure-sensitive (demand) pump which turns itself off until there is a demand for water.
Max head (nominal) 35 metres, pump pressure (nominal) at outlet 3.5 bar, max suction 3 metres.
Dry-run Protection: when no water is detected for 8 seconds, the pump is turned off by the printed circuit board (PCB) in order to protect the motor and pump from burning out.
Automatic reset after a period of 30 minutes. If water is still not detected, subsequent reset periods are 1.5 hours, 3 hours, 7 hours, 12 hours, 24 hours then back to the beginning of the cycle. Additionally, a thermal switch, not connected to the PCB, turns the pump off when motor overheats. It resets when cool which make take several hours.
Alloy bulkhead (pictured below), pressure release gap and twin chamber design prevents ingress of water to motor, electrical components and to bearing oil.
Double bearing seal prevents egress of bearing oil.
Alloy bulkhead dissipates motor heat to water in the second chamber.
Logic processors in PCB prevent other pump anomalies and permit factory programming of reset timings.
Guaranteed for 2 years.
Electricity consumption 800 watts at 220-240 Volts AC 50 Hz (requires 10 or 13 amp fuse and RCD mains socket). Connection cable 10m H07RN-F.
Inlet port to the non-removable filter 1 inch (25mm) female BSP. Output port 1 inch (25mm) female BSP provided with push-fit connector for 1 inch (25mm) MDPE pipe (11/4 inch (32mm) connector option by special order).